GoldSys ->






 Vai para Home Page!

::Calculadora::

Calculadora!

Pedido!

Dúvidas!

Associado!

Chat!

Boa Noite! 7 de Fevereiro de 2012.

Vai para Home Page
Adicionar à Favoritos!

Ser sua Página ínicial!

::INSTITUCIONAL::
   A GoldSys
   Área de Atuação
::PRODUTOS::
   Automação
   Tecnologia
   Suprimentos
   Soluções
::SERVIÇOS::
   Assistência Técnica
   Boletim Tecnológico
   FAQ - Perguntas Freq.
   Links Importantes
Você é o visitante n
Tem 39 usuários online!

VISION TRACK

   

A complete eye and head tracking system. This head-mounted, turn key solution allows unrestricted head movement while it collects pupil size, eye movement, and eye point-of-regard data from human subjects.

 
  • COMPONENTS
     
  • Eye/Scene Imaging System (Mounted on Baseball Cap)
    • · Ultra-lightweight, miniature eye and scene imaging electronic and optical component assemblies generate eye and scene video images for virtually any subject.
  • Pupil/Corneal Reflection Tracking Circuit Card (Installed in Computer Chassis)
    • · Eye tracking processor tracks center of subject’s pupil and a reflection from the corneal surface and measures pupil size, all in real-time.
  • Autocalibration Circuit Card (Installed in Computer Chassis)
    • · Autocalibration processor calculates subject’s fixations with respect to scene being viewed. Real time fixation is represented as a cursor on operator’s scene monitor and may be output in serial format from the PC
    • · Output data is in NTSC format and can be recorded with an external VCR
  • Eye Monitor
    • · 9-inch black and white monitor for viewing video from eye camera.
  • Scene Monitor
    • · 9-inch black and white monitor for viewing video from scene camera
  • Computer System
    • · Dell computer system includes computer chassis, color monitor, mouse, and keyboard.
       
  • FEATURES
    • · Highly accurate, real time eye tracking
    • · Collects pupil size, eye movement and point of regard data in real time
    • · Simultaneously measures head and eye movement
    • · Easy and Flexible setup
    • · Adaptable lightweight headgear
    • · Easy data collection
    • · System calibrates in minutes
    • · Sophisticated built in data analysis software
    • · Data is stored in ASCII
    • · System is fully functional under virtually any lighting conditions
       
  • APPLICATIONS
    • · Human Factors Evaluation
    • · Military Simulation and Training
    • · Vision Research
    • · Psycho-visual Experiments
    • · Drug and Alcohol Response Testing
    • · Surgical Simulation and Training
    • · Handicapped Communication
    • · Advertising/Web Evaluation
    • · Retail Effectiveness Assessment

    •  
  • SPECIFICATIONS
     
  • Imaging Environment
  • · Fully functional under dark or bright lighting
  • · Parallax-free scene imaging means that subject point-of-gaze calibration is accurate over full depth of focus
  • Subject Requirements
    • · Wide range of subject acceptance: eyeglasses, sunglasses, contact lenses, drooping eyelids easily accommodated.
    • · Ultra-lightweight of eye/scene imaging assemblies allows mounting to virtually any headgear. (Weight of eye/scene imaging assembly w/ cap: approx. 8.5 ounces)
    • · Complete subject mobility while recording pupil size and point-of-regard information with respect to surrounding environment.
  • Eye Tracking
    • · Pupil tracking methodology separates pupil from dark shadows or eyelashes in eye image
    • · Resolution: 1500 units horizontal x 2200 units vertical
    • · Built-in fixation monitoring and blink detection
    • · Pupil measurements include horizontal diameter, vertical diameter, and pupil area
  • Update Rate
    • · 60 Hz update rate (upgradeable to 120 or 240 Hz)
  • Interface
    • · RS-232 serial interface for all eye data parameters
  • Accuracy/Eye Movement Range
    • · Point-of-regard accuracy typically <0.5 degrees over +/-25 degrees horizontal and +/-20 degrees vertical range
    • · Extended range calibration procedure tracks eye movement over +/-40 degrees horizontal and +/-30 degrees vertical range
  • Ease of Use
    • · System set-up and subject calibration are both simple and flexible
    • · Data collection and calibration procedures are performed from operator’s PC console
    • · Subject calibration procedure typically takes less than 3 minutes
    • · Stored data is in ASCII format for later retrieval, analysis, and exporting
  • Analysis Software
    • · Operator configurable software includes scrolling graph displays to view data
    • · Recorded parameters such as raw data, velocity, or acceleration can easily be displayed
    • · Automatically computes average, maximum, minimum, and standard deviation
    • · Correlates subject fixations to objects within the viewed scene
  • Power Requirements
    • · 115/230 VAC, 60/50 Hz

    | Equipamentos | Associado | Tecnologia | Pedido | Assistência Técnica |

    | FAQ | Links | A Empresa | Cadastramento | Fale Conosco

    Resolução mínima de 800x600 © Copyright 1988-2011
    GoldSys Informática LTDA.
    webmaster@goldsysonline.com.br